A certificate of analysis (COA) is only useful if you can read what it actually measured and check it with the laboratory that issued it. This guide shows how to read a research-peptide COA, then walks through a real certificate from our Lab Results page and lists the independent laboratories named on the supplier batch certificates we publish, with what each certificate shows. Everything here is for laboratory research use only.

What a peptide COA is, and what it is not

A COA is a laboratory report for a submitted sample, identified by a lot, batch or report number, issued by a named laboratory on a stated date, with named methods and results. It is not a product brochure, not a Health Canada authorization, not a sterility guarantee for every vial, and not proof that a material is suitable for human use.

Our Lab Results page says the certificates are published “exactly as each laboratory issued them,” by laboratories “which we do not own or operate.”

Supplier certificates vs. our own tests

Two kinds of certificate appear on our Lab Results page, and every one is labelled by who it was issued to:

  • Vistara-commissioned tests. Some certificates on the Lab Results page were commissioned by Vistara Labs directly and name Vistara Labs as the client. Open them from that page.
  • Supplier batch certificates. All other certificates were issued to our suppliers for their batches, and each is captioned “Supplier batch certificate (issued to [supplier])”, for example issued to Aurevia Bioscience, JMI, Wholesale, PeakForce Labs, AgeREcode or CertaPeptides. Supplier certificates are a normal part of research supply: the manufacturer or distributor tests a batch before it is sold on.
  • To use a supplier certificate, match the supplier lot or batch number printed on the certificate to the lot on the vial you receive. Where a certificate shows lot “N/A”, it cannot be matched to a specific vial.

Check these four things first

1. The lot, batch or report number

If the identifier on the vial or listing does not match the certificate, stop: the rest of the document does not describe that unit.

2. The laboratory’s name

A usable COA names an independent laboratory. The supplier batch certificates on our Lab Results page were issued by AV Analytics, Testides, Bioviridian, Freedom Diagnostics, Chromate and Janoshik Analytical.

3. The dates and the identifiers

Look for sample received, analyzed and reported dates, plus a report, accession or task number you can type into the laboratory’s own lookup page.

4. The methods, not just the headline percentage

Look for named methods (HPLC or UPLC, LC-MS or HPLC-MS/MS, and any endotoxin or metals method) and for the chromatogram or spectrum, not only “99%”.

How to read the results

HPLC (or UPLC) purity

Chromatographic purity is usually the area percentage of the main peak at the stated wavelength (214 nm on several of our certificates). It describes the material the method separates and detects. On its own it does not give milligrams in the vial, confirm identity, or rule out water, salts, counter-ions or unreported contaminants. Our Lab Results page puts it this way: “The purity figure comes from high-performance liquid chromatography (HPLC): it shows how much of the sample is the target compound. We do not stock material below 99% chromatographic purity.”

Mass spectrometry and identity

Identity is a separate question: does the measured mass or fragmentation agree with the stated compound? A clean HPLC peak could in principle be the wrong molecule, which is why identity is reported separately. Mass agreement does not resolve every isomer or sequence variant.

Net peptide content and fill accuracy

Where a report gives milligrams measured against the label amount, that is a quantity result, not a purity result. A sample can have high purity and still contain more or less than the labelled milligrams.

Tests that are often absent

Endotoxin, sterility or microbial tests, and heavy metals are separate analyses. If they are not on the certificate, treat them as not reported. A 99% purity line is not a pass on those tests.

Walk-through: a Freedom Diagnostics KPV certificate

The example is the supplier batch certificate for KPV 10 mg from Freedom Diagnostics, KPV_CoA_Jul2026.pdf, linked from the Lab Results page. It is a useful example because it reports a lot number, two vials and tests beyond purity.

  • Header and client. Laboratory: Freedom Diagnostics. Client: Wholesale (the supplier). Accession 2607080001, search code Whol2607080001. Received 8 July 2026, reported 10 July 2026.
  • Lot. KPV10-072026-1. This is the identifier to match against the lot on a vial.
  • Method. “HPLC with UV detection coupled with mass spectrometry (LC-MS).”
  • Separate results. Identity (LC-MS): KPV. Purity (HPLC-UV): 99.89% and 99.87% for the two vials, 99.88% overall. Net content: 10.35 mg and 10.66 mg, an average of 10.51 mg against a 10 mg label. Purity and content are different numbers answering different questions.
  • Tests beyond purity. Endotoxin by Limulus Amebocyte Lysate assay in accordance with USP <85>, two replicates, both “Pass” at an assay sensitivity of ≤0.05 EU/mL. Microbial analysis by PCR: “No Detectable Microbial DNA”. Sterility and heavy metals are not reported.
  • Verify it yourself. Open the Freedom Diagnostics accession-number lookup (linked in the table below) directly, enter the accession number, and check that the laboratory’s copy shows the same compound, lot, dates and results.
  • The limits. The certificate states the analysis “is specific to the sample(s) provided” and that the peptides tested “are intended for research use only and are not approved for human or veterinary use, diagnostic, therapeutic, or clinical applications.”

The laboratories on our supplier certificates

As of 18 November 2026, these laboratories issued the supplier batch certificates on our Lab Results page. Each entry describes only what appears on the certificates we publish. Certificates commissioned by Vistara Labs directly are also listed on that page.

AV Analytics

Supplier batch certificates (issued to Aurevia Bioscience). 10 certificates: Tesamorelin, Tirzepatide, Ipamorelin, Epitalon, Kisspeptin, PT-141, Cagrilintide, Cartalax, Melanotan II, Pinealon. They show UPLC-UV purity (% area), UPLC-MS identification, quantitative UPLC net content and an endotoxin result by recombinant Factor C (rFC) assay. Example: Tesamorelin, COA-2026-0193, issued 3 September 2026, client lot 00011/0011, average purity 99.79%, endotoxin 0.08 EU/mL against a <0.5 EU/mL criterion. Heavy metals and sterility are not reported.

Testides

Supplier batch certificates (issued to JMI). 3 certificates: DSIP, GLOW Blend, Semax. They show HPLC-UV purity and content at 214 nm, expected vs measured mass in milligrams, and fill accuracy. Lot is printed as “N/A”. A separate mass-spectrometry identity result is not shown on these certificates. Example: Semax 10 mg, report PBC-SEMAX-10mg-051026: 10.03 mg measured against 10.00 mg expected, purity 99.78%, fill accuracy 100.3%.

Bioviridian

Supplier batch certificates (issued to Aurevia Bioscience). 3 certificates: 5-Amino-1MQ, Glutathione, IGF-1 LR3. They show identity by LC-MS/MS, content by HPLC quantitation, purity by RP-HPLC at 214 nm, a chromatogram and a mass spectrum. Example: 5-Amino-1MQ, web verification code COA6599, issued 21 July 2026: identity conforms, content 10.33 mg, purity 99.8%. All three certificates show lot 00011.

Freedom Diagnostics

Supplier batch certificates (ARA-290 and KPV issued to Wholesale; VIP issued to PeakForce Labs). They show HPLC-UV purity with LC-MS identity, net content, and endotoxin by LAL assay (USP <85>, two replicates). The KPV 10 mg certificate is the walk-through example above.

Chromate

Supplier batch certificate (issued to AgeREcode). 1 certificate: Snap-8 10 mg, COA #33262, batch H.012526, analysis 18 March 2026, by RP-HPLC with UV detection: identity conforms, quantity 10.48 mg, purity 99.735%, metals <50 ppb. Mass spectrometry, sterility and endotoxin are not reported.

Janoshik Analytical

Supplier batch certificate (issued to CertaPeptides). 1 certificate: Cerebrolysin, task #212145, LC-MS screening plus CHNS total-nitrogen analysis (total nitrogen 12.17 mg). This is a content assay, not a single-peptide HPLC purity result, which is why the Lab Results table lists it as “Content verified”.

How to verify a report with the laboratory

Open the laboratory’s site yourself rather than trusting only a QR code or a seller-hosted copy. A match confirms the laboratory issued that report for the sample it received; it does not re-test the vial in your hands.

LaboratoryWhat to enterOfficial lookup
AV AnalyticsCertificate / search codewww.avanalytical.com/coa-search
TestidesComplete report numbertestides.com/verify/
BioviridianWeb verification codebioviridians.com/coa-search.html
Freedom DiagnosticsAccession numberfreedomdiagnosticstesting.com/search-for-your-coa-based-on-the-unique-accession-number/
ChromateCOA number and access codechromate.org/verify
Janoshik AnalyticalTask number and unique key printed on the reportjanoshik.com/verify/

Red flags, and the limits of a good report

  • No laboratory name, or a document that does not name any laboratory.
  • No lot or report number, or one that does not match the vial.
  • A purity figure with no method or no chromatogram.
  • “Identity confirmed” with no mass or method stated.
  • Chromatograms that look identical across different lots.
  • A test date that cannot be reconciled with the listing.

Even a good report covers one submitted sample, on one date, by the methods stated. It is not a licence to use the material in humans and it does not replace a laboratory’s own controls.

Where to see our certificates

The full table is on our Lab Results page. As of 18 November 2026 these products are marked “COA pending” there: AOD-9604, BPC-157 + KPV Capsules, Dihexa, KPV Capsules, SLU-PP-332 and VIP Nasal Spray. For how prices compare across Canadian shops, see the Canadian Peptide Price Index; for the regulatory background, see Are peptides legal in Canada? Questions about a report are welcome through our contact page. All products are sold under our Research Use Policy.

Frequently asked questions

How do I read a peptide certificate of analysis?

Start by matching the lot, batch, or report number on the certificate to the vial or the product listing; if they do not match, the document does not describe that material. Then confirm it names an independent laboratory, a test or issue date, and a report number you can look up on the lab’s own site. After that, read the results as separate lines: HPLC or UPLC purity is the share of the main peak under that method, mass spectrometry speaks to identity, and net peptide content (when reported) is the amount measured in the submitted sample. A COA is a record of those tests on that sample, for laboratory research use; it is not a Health Canada authorization and it is not a safety or efficacy certificate.

What do HPLC purity and mass spectrometry tell you on a peptide COA?

HPLC (or UPLC) purity is usually an area percentage: how much of the detector-visible, chromatographically separated material is the main peak, under the stated method and wavelength. It does not, by itself, confirm which molecule that peak is, and it does not measure water, salts, counter-ions, or unreported contaminants. Mass spectrometry compares an observed mass with the mass expected for the stated compound, which supports identity. The two results answer different questions, which is why a complete research COA typically reports both, or makes clear when one of them was not done. Neither result is a licence for human or veterinary use.

How can I verify a Vistara Labs peptide COA?

Open the certificate from our Lab Results page, note the issuing laboratory, who the certificate was issued to, and the report, accession or verification code. Then enter that identifier on the laboratory’s own lookup page, for example the Freedom Diagnostics accession-number search. The lab’s copy should show the same compound, date and results as the PDF. A match confirms the laboratory issued that report for the sample it received; it does not re-test the vial in your possession. Each certificate on the Lab Results page shows who it was issued to.

For laboratory research use only. Not for human or veterinary use. Certificates are published as issued by independent laboratories that Vistara Labs does not own or operate.